4 modbus rs485 operation – Bronkhorst EL-FLOW Base 2014 User Manual

Page 15

background image

BRONKHORST HIGH-TECH

Examples of DDE client applications: FlowPlot, FlowView, MS-Office, LabView, Intouch, Wizcon.

The FLowDDE server also offers a lot of test facilities and user adjustable settings for efficient

communication with the connected flow controller.

How to setup a DDE link with FlowDDE is described in the help-file of the FlowDDE application.

Programming examples are available for making applications in: Visual Basic, LabView and Excel.

FLowDDE parameter numbers:

Reading/changing parameter values via FLowDDE offers the user a different interface to the instrument.

Besides the application name: ‘FLowDDE’ there is only need of:

• topic, used for channel number: ‘C(X)’

• item, used for parameter number: ‘P(Y)’

A DDE-parameter number is a unique number in a special FLowDDE instruments/parameter database

and not the same as the parameter number from the process on an instrument.

Node-address and process number will be translated by FLowDDE to a channel number.

FlowDDE and other Bronkhorst applications are available at the Bronkhorst download site:

http://www.bronkhorst.com/en/downloads

A special RS232 cable (7.03.366) can be ordered separately. It consists of a T-part with 1 male and 1

female sub-D 9 connector on one instrument-side and a normal female sub-D 9 connector on the side of

the computer. By means of this cable it is possible to offer RS232 communication and still be able to

connect power-supply and analog interface through the (analog) sub-D 9 connector.

3.4

Modbus RS485 operation

This chapter is limited to the description of the interface between the Modbus Mass Flow Controller

with a master device. It will explain how to install an EL-FLOW Base instrument to your Modbus system.

It only contains the information that is needed most.

The implementation of the Modbus interface is based on the following standards:

[1] MODBUS Application Protocol Specification V1.1b, December 28, 2006

[2] MODBUS over Serial Line specification and implementation guide V1.02

There is no mutual communication between Modbus slaves; only between master and slave.

More detailed information about Modbus can be found at

http://www.modbus.org

or any website of

the (local) Modbus organisation of your country (when available).

Base

FlowDDE

server

Application 1

Application 2

Application n

RS232

DDE-link

DDE-link

DDE-link

Windows based Personal Computer

Instrument

9.17.061

EL-FLOW Base Series Mass Flow Controllers

Page 15