beautypg.com

2 installation instructions, 1 introduction, 2 unpacking and inspection – Bronkhorst EL-FLOW Base 2014 User Manual

Page 10: 3 rated pressure test inspection, 4 instrument mounting

background image

BRONKHORST HIGH-TECH

2 Installation Instructions

2.1

Introduction

This chapter discusses how to prepare the system and install an EL-FLOW Base mass flow controller.

2.2

Unpacking and inspection

Check the outside packing box for damage incurred during shipment. Should the packing box be

damaged, then the local carrier must be notified at once regarding his liability, if so required. At the

same time a report should be submitted to your distributor.

Carefully remove the equipment from the packing box. Verify that the equipment was not damaged

during shipment. Should the equipment be damaged, then the local carrier must be notified at once

regarding his liability, if so required. At the same time a report should be submitted to your distributor.

Refer to chapter 6, Removal and Return Instructions, about return shipment procedures.

Before installing an EL-FLOW Base it is important to read the attached label and check:

- Flow rate

- Fluid to be measured

- Up- and downstream pressures

- Input/output signal

- Temperature

Do not discard spare or replacement parts with the packing material and inspect the contents for

damaged or missing parts.

2.3

Rated pressure test inspection

Each EL-FLOW Base is pressure tested to at least 1.5 times the working pressure of the process

conditions stipulated by the customer, with a minimum of 8 bar.

Pressure testing sticker

Each instrument is helium leak tested to at least 2⋅10

-9

mbar l/s Helium outboard.

The tested pressure is stated on the flow controller with a RED COLOURED sticker. Check test pressure

before installing in the line.

If the sticker is not available or the test pressure is incorrect, the instrument should not be mounted in

the process line and be returned to the factory.

2.4

Instrument mounting

The bottom side of an EL-FLOW Base consists of two mounting holes for stable mechanical fixation of

the instrument. Refer to the following documents for exact position of the mounting holes.

Dimensional drawing F-201AB, document nr. 7.15.165.

Dimensional drawing F-201CB, document nr. 7.15.166.

Dimensional drawing F-202BB, document nr. 7.15.170.

The preferred mounting position of EL-FLOW Base mass flow controllers is horizontal. Other mounting

positions may introduce a zero shift and/or little gas and pressure dependency of the zero signal. When

Page 10

EL-FLOW Base Series Mass Flow Controllers

9.17.061