beautypg.com

Certificates, Ce conformity, Service data – Avery Dennison TTX 450 User Manual

Page 38

background image

User Manual

TTX 450/650/950/1050 – Puma/Lion/Tiger/Tiger XXL – TDI/STDI/XXtreme –

S45/65/95/105

05/08 Rev.

2.14

38

Weight

Approx. 25kg - without stock

Interfaces

Standard: serial (RS 232) and parallel (Centronics) optional RS 485 -
in exchange against RS 232

Memory

1MB dynamic RAM

Cards

2 Slots for PCMCIA cards, 2 MB each

Certificates

TÜV GS

Approved security (according to EN 60950:97)

CE conformity

The devices are marked with the CE label. The manufacturer
declares that the device conforms with the relevant European
guidelines.

EMC

The EMC tests were performed according to the following norms:

EN

55022:98

EN 55024:98
EN 61000-3-2:95
EN 61000-3-3:95
EN 61000-6-2:99

Service Data

The data shown in STA3 can have a maximum value – shown in the table below. After that
value is reached the counter is set to zero and counts up again.

Number of service operations

255

Number of heads / rolls / knives

255

Head / roll run length

131 km

Cuts on knife

4.300.000.000

Total material length

430.000 km

Total foil length

430.000 km

Total number of cuts

4.300.000.000

Head moves

4.300.000.000

Head strobes

4.300.000.000

Operation time

8.800 years