Positioning of gap sensor

Depending on the printer different sensor are possible. Using the TDI two sensor are
available – through light and reflective. Using the TTX three sensor are possible (through
light, reflective and full size).

Between trough light and reflective there is a difference of 11 mm (adding). The optional full
size sensor is behind the standard sensor. The sensor can be moved across the web – and
the gap can be sensed . The minimum label width is extended to 38 mm.

Adapt sensor to the position of the gap by means of the adjusting knob located at the front

side of the print module.

Adjustment range: 2-15mm

across the web.

• A scale is marked around the knob

• Calculate position as follows. Measure distance between center of gap and left

edge of material reduce value. by 2 the results matches the adjustment value at
the scale

Sample :

Distance between center of gap and left edge of material 11mm

Reduction - 2mm

Adjustment value 9mm

With round labels punch - offset pre adjustment is possible at the printer (parameter

PUNO) or via Easy Plug command in order to correctly catch the label edge.