Avery Dennison 9850 RFID Multi-Protocol User Manual
Page 44
![background image](https://www.manualsdir.com/files/773105/content/doc044.png)
A-2 Single Protocol Encoding
Option Choices
Default
Read Tag
NA
NA
Find Retries
1-5
3
Erase Retries
1-5
3
Program Cycles
1-5
3
Lock Attempts
1-5
3
Attenuation 2-10
5
Clear Data
Yes/No
No
Print Config
Yes/No
No
Lock Attempts
The number of times the interrogator tries to lock the RFID tag in the RF
Field. When a tag is locked, the data cannot be reprogrammed. See
“Using Option 63,” for more information.
If the interrogator fails to lock the RFID tag, an RFID error is generated.
See “RFID Errors” for more information. When an RFID error is
generated, you may want to print an overstrike pattern. See “Setting the
Error Action” for more information.
If the RFID tag is locked on the first try, the module proceeds to the next
step in the cycle. If not, the module attempts to lock the tag up to the
Lock Attempts setting. The range is one to five, with a default setting of
three. Maximum throughput results when tags are locked on the first try.
To change the setting, from the Main Menu, select Setup, then RFID.
Then follow these steps.
1. Press Å or Æ until you see
RFID
Å
Lock
Attempts
Æ
2. Press Enter/Pause. The current setting is displayed, for example:
Times to Lock
[1/5]: +3
3. Press Å or Æ to increase or decrease the setting. After you display
the option you want, press Enter/Pause.
4. Press Escape/Clear until you see the Main Menu.