beautypg.com

Optional equipment, Remote thermostat, For qualified installers only) – Avalon Firestyles DVL Fireplace-1999 to 2002 User Manual

Page 51: Travis industries

background image

Optional Equipment

(for qualified installers only)

4 9

Travis Industries

4 0 2 0 8 1 2

9 3 5 0 8 1 1 0

7

Place the included propane label over the natural gas
label on top of the gas control valve.

THIS CONTROL

HAS BEEN

CONVERTED TO

LP

8

With the glass removed, bleed the gas line (if applicable) and start the pilot (see the directions on page
37). Leak-test all gas connections and the regulator. Check the pilot. Adjust if necessary. Replace
the glass and face.

WARNING:

When lighting or re-lighting the pilot, the glass must be removed (see
page 37).

The pilot flame must contact the thermocouple and

thermopile (see the illustration below). Adjust the pilot up or

down as necessary.

PILOT ADJ

T

O

L

PI

ON

OFF

Standard
Screwdriver

Micro (1/16”)
Standard
Screwdriver

Cover Screw

Cover Screw Gasket

Needle Valve

To adjust the pilot flame,

remove the cover screw

and gasket and turn the

needle valve (NOTE: if

the needle valve is totally

unscrewed, gas will come

out of this port).

Clockwise lowers the

flame while counter-

clockwise raises it.

Replace the cover screw

and gasket.

Remote Thermostat

(Part # 99300651)

!

Do not connect 110-120 VAC to the gas control valve or wiring system of this unit.

Follow the instructions included with the remote thermostat for installation.

IMPORTANT OPERATIONAL NOTE FOR REMOTE THERMOSTAT USE:

Included with the remote thermostat is a set of instructions that should be given to the homeowner.
Please be aware that the remote thermostat has a 1 to 2 minute lag time between the time the
thermostat is turned up and the heater turns on.