1 8
Installation
(for qualified installers only)
Travis Industries
4 0 2 0 8 1 2
9 3 5 0 8 1 1 0
Altitude Considerations (Rear Vent Configuration)
This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
!
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Approved Vent Configurations (Rear Vent Configuration)
•
The vent must terminate horizontally.
•
Maximum 6’ of Vent Length (not including elbow and termination)
•
1 Elbow Maximum (45° or 90°)
DVL Fireplace
One Elbow Maximum
(90° or 45°)
Maximum 6' Length
(determined by adding H1 + H2)
Maximum 6' Length
H1
H2
Approved Vent Components for Rear Vent Configuration
Description
Part #
Packing List
Straight Installation Kit
98900170
Rear Vent Adapter
Wall Thimble
Horizontal Vent Termination (Cap)
Corner Installation Kit
98900171
Rear Vent Adapter
45° Elbow
7” Adjustable Vent Length
Wall Thimble
Horizontal Vent Termination (Cap)
7” Adjustable Vent Length
98900172
7” Adjustable Vent Length
24” Vent Length
98900173
24” Vent Length
36” Vent Length
98900174
36” Vent Length
12” Adjustable Vent Length
98900175
11-9/16” to 15-3/8” Adjustable Length
Horizontal Termination Cap
98900176
Cap
45° Elbow
98900177
45° Elbow
90° Elbow
98900178
90° Elbow
Wall Thimble
98900179
Wall Thimble (two mating pieces)
Vinyl Siding Standoff
98900180
10” Vinyl Siding Standoff
Rear Vent Adapter
98900181
Rear Vent Adapter