Installation

(for qualified installers only)

Travis Industries

4 0 2 0 8 1 2

9 3 5 0 8 1 1 0

Altitude Considerations (Rear Vent Configuration)

This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

!

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Approved Vent Configurations (Rear Vent Configuration)

The vent must terminate horizontally.

Maximum 6’ of Vent Length (not including elbow and termination)

1 Elbow Maximum (45° or 90°)

DVL Fireplace

One Elbow Maximum

(90° or 45°)

Maximum 6' Length

(determined by adding H1 + H2)

Maximum 6' Length

H1

H2

Approved Vent Components for Rear Vent Configuration

Description

Part #

Packing List

Straight Installation Kit

98900170

Rear Vent Adapter

Wall Thimble
Horizontal Vent Termination (Cap)

Corner Installation Kit

98900171

Rear Vent Adapter

45° Elbow
7” Adjustable Vent Length
Wall Thimble
Horizontal Vent Termination (Cap)

7” Adjustable Vent Length

98900172

7” Adjustable Vent Length

24” Vent Length

98900173

24” Vent Length

36” Vent Length

98900174

36” Vent Length

12” Adjustable Vent Length

98900175

11-9/16” to 15-3/8” Adjustable Length

Horizontal Termination Cap

98900176

Cap

45° Elbow

98900177

45° Elbow

90° Elbow

98900178

90° Elbow

Wall Thimble

98900179

Wall Thimble (two mating pieces)

Vinyl Siding Standoff

98900180

10” Vinyl Siding Standoff

Rear Vent Adapter

98900181

Rear Vent Adapter