Operation

Travis Industries

4 0 2 0 8 1 2

9 3 5 0 8 1 1 0

Before You Begin

Warning: Read this entire manual before you use your new fireplace (especially the section "Safety

Precautions" on pages 2 & 3). Failure to follow the instructions may result in property
damage, bodily injury, or even death.

Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of

the glass should be done by a licensed or qualified service person.

Location of Controls - See explanation below

Swing the control cover down

to access the gas control valve,

igniter, and blower control.

Gas Control

Valve

PILOT ADJ

VENT

T

O

L

PI

ON

OFF

HI

LO

Gas Control

Knob

Flame Adjust

Knob

Blower Knob

BLOWER

LO

OFF

HI

PILOT

IGNITER

Pilot Igniter

ON/OFF Switch

The Pilot Flame can be found below

the back log on the left side.

ON

OFF

MAIN BURNER

Blower Knob

This knob controls the speed of the internal convection blower that pushes
the heated air into the room.

On/Off Switch

This control is used to turn the fireplace on and off.

Pilot Igniter

The pilot igniter is used only to start the pilot. When pressed, it sends an
electrical charge to the pilot assembly. This creates a blue spark directly next
to the pilot, igniting the pilot flame.

Gas Control Knob

This knob is used to control gas to the fireplace and for starting the pilot.
There are three positions, ON, OFF, & PILOT. The pointer directly below the
knob indicates the position this knob is in.

Flame Adjust Knob This knob controls the flame height from low ("LO") to high ("HI"). The pointer

to the upper left of the knob points to the position this knob is in.

?

If using a remote control or thermostat, the On/Off Switch must be left "ON". Turning the On/Off
Switch "OFF" will keep the fireplace off always.