Installation, Rear vent configuration – Avalon Firestyles DVL Fireplace-1999 to 2002 User Manual
Page 19
Installation
(for qualified installers only)
1 7
Travis Industries
4 0 2 0 8 1 2
9 3 5 0 8 1 1 0
Rear Vent Configuration
!
The vent must maintain the required clearance to combustible materials to prevent a fire (see
“Clearances and Installation Requirements” below). Do not fill air spaces with insulation.
!
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
!
When using the rear vent configuration, you must use the vent components listed under “Approved
Vent Components” below. No substitutions, modifications, or alterations to the vent kit are allowed.
Installing the Rear Vent Adapter (included with the rear vent kits)
Remove the rear vent cover.
1/4" Nutdriver
a
b
Remove the rear
vent exhaust cover
(and gasket).
7/16" Wrench
c
d
Apply a 1/8" thick bead of high-
temperature (600° F.) silicone to the
inside of the exhaust vent.
Install the rear vent adapter.
1/4" Nutdriver
Silicone
NOTE: the upper edge of the
adapter is shorter than the
sides and bottom edges.
NOTE: use a 1/8" drill, if necessary, to
make holes for the mounting screws.