Installation, Corner installations, Raised fireplaces – Avalon Firestyles DVL Fireplace-1999 to 2002 User Manual

Page 10

background image

8

Installation

(for qualified installers only)

Travis Industries

4 0 2 0 8 1 2

9 3 5 0 8 1 1 0

Clearances

When installed, walls in front of the fireplace must be a minimum 6" to the side of the faceplate.

Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of
the fireplace (e.g. drapes, doors)

Fireplace must be placed so the vents below and above the glass do not become blocked

Corner Installations

A typical 45° installation uses the minimum framing dimensions shown in the illustration below.

19-3/8"

1" Standoffs

Min. 1" Clearance to

Fireplace Enclosure

47-5/8"

13-3/4"

14-3/4"

10" Diameter Pipe
(7" Length)

7"

45° Elbow

Thimble
(opening is 14-1/2"
high x 13" wide)

DVL Fireplace

50-1/2"

Termination

MinimumClearances from

Pipe To Combustibles:

• 1-1/2" to the Sides & Below

• 3" Above

Top Vent Configuration

Rear Vent Configuration

NOTE:

the fireplace may require a

larger enclosure to allow for

the vent to pass through the

framing.

1-1/2" (min. clearance)

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(approximately 300 Lbs.) and vent.

The fireplace may not be raised so as to place the ceiling within 24” of the top of the faceplate.

Raised fireplace

Raised fireplace with
raised hearth.

Raised
Platform

Nail the nail down plates to the floor
(or raised platform)

Raised Hearth

Hearth

Raised
Platform