background image

2 6

Installation

(for qualified installers only)

Travis Industries

4 0 2 0 8 1 2

9 3 5 0 8 1 1 0

Horizontal Terminations with 1 Vertical Elbow (Top Vent Configuration)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.

NOTE:

• One horizontal elbow (45° or 90°) is allowed. The

horizontal vent length is calculated by adding the length
before and after the elbow (H1 + H2 = horizontal vent
length).

• Horizontal sections require a 1/4" rise every 12" of travel.

• The maximum vertical height is 20'.

• The maximum horizontal length is 24'.

H1

Horizontal Elbow

(45° or 90°)

Vertical

Elbow

H2

5 feet

0 feet

0 feet

24' (max)

5 feet

0 feet

24' (max)

20' (max)

20' (max)

5 feet

10 feet

5 feet

10 feet

0 feet

15 feet

20 feet

10 feet

15 feet

15 feet

20 feet

10 feet

15 feet

Min. 24" Rise

Before First Elbow

Restrictor

Position #1