beautypg.com

Avalon Firestyles B-Vent-1995 User Manual

Page 5

background image

F

EATURES AND

S

PECIFICATIONS

P

AGE

5

Installation Options:

¥ Freestanding

¥ Masonry Fireplace Insert

¥ Zero-Clearance (Metal)

Fireplace Insert

Features:

¥

Works During Power Outages
(millivolt system)

¥

High Efficiency; 80% Natural Gas, 82% LP
(Steady State)

¥

Optional Thermostat or Remote Control

¥

Realistic "Wood Fire" Look

¥

Convenient Operating Controls

¥

Variable-Rate Heat Output

¥

Quiet Blower for Effective Heat Distribution

¥

Low Maintenance

Heating Specifications:

Natural Gas

LP (Propane)

Approximate Heating Capacity (in square feet)*

600 - 1600

600 - 1600

High Burn Input Rate (In BTU's)

31,000

31,000

Low Burn Input Rate (In BTU's)

18,000

17,000

Efficiency**

80%

82%

AFUE (Annuel Fuel Utilization Efficiency)

70%

70%

*

Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.

**

Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system.
To measure the net BTU's, multiply the BTU input by the efficiency percentage (80% for natural gas, 82% for LP).

Dimensions

20"

24-1/2"

12-1/4"

3-1/4"

31-1/4"

Vent Dia. 4"

28-3/4"*

8x10

Panels

31-3/4"*

10x13

Panels

3-1/8"

11-3/8"*

7-7/8"*

* Includes trim & standoffs

40-1/4"* 8x10 Panels
44-1/4"* 10x13 Panels

Location of optional 45¡
vent adapter (from the back
and bottom of the insert).

18-1/4"

1-3/8"

20-3/8"

21-3/4"

Standoff

Fuel:

The heater is designed either for natural gas or for propane (but not
for both). Check the sticker on the top of the gas control valve.

Emissions:

This unit has passed the ANSI emission standards for vented room
heaters as tested by Warnock Hersey, LTD.

Electrical Specifications:

115 Volts, 1.3 Amps, 60 Hz (150 watts on high)

This manual is related to the following products: