For qualified installers only!

P

AGE

15

Vent Termination Requirements

¥

Vent termination must have an approved cap (to prevent water from entering)

¥

Vent termination must not be located where it will become plugged by snow or other material

¥

Vent termination must be 1' above the roof and meet the requirements outlined in ANSI Z223.1,
section 7.6.2.

1' Minimum

Note: ANSI 223.1, section 7.6.2 outlines
additional requirements for gas vent terminations.
If your installation involves a roof with a slope
greater than 6/12 or if a wall or other verical
obstruction is within 8' of the vent termination, the
vent termination will need to be taller. Refer to
ANSI 223.1 for full details.

!

When installed, the vent must provide suitable draft for the appliance. Other factors, such as exhaust
fans, may create negative pressure inside the home and cause down drafts. Additional vent height
may be required in these circumstances.

Electrical Connection

¥

Plug the power cord into a grounded 110 Volt outlet (do not remove the grounding plug).