beautypg.com

Avalon Firestyles B-Vent-1995 User Manual

Page 32

background image

P

AGE

32

T

ROUBLESHOOTING

Problem:

Possible Cause:

Don't Call for Service

Until You:

Pilot Will Not Light

A gas shut off valve is turned off

The valve control knob isn't turned to "PILOT"

The valve control knob isn't pushed in

The igniter wasn't pressed repeatedly

Check all gas shut off valves

See "Starting the Pilot Light" Step C

See "Starting the Pilot Light" Step C

See "Starting the Pilot Light" Step C

Main Burners Will Not

Start

The pilot light has gone out

The ON/OFF switch is turned to "OFF"

The remote control is not working correctly

The thermostat is disconnected or set too high

See "Starting the Pilot Light"

Turn the ON/OFF switch to "ON"

See "Remote Control Operation"

See "Thermostat Operation"

Remote Control Does

Not Work

The pilot light has gone out

The ON/OFF switch is turned to "OFF"

The remote is too far away from the heater

The remote control receiver is turned "Off" or "On"

One of the two remote control batteries is dead

See "Starting the Pilot Light"

Turn the ON/OFF switch to "ON"

Use the remote closer to the heater

See "Remote Control Operation"

See "Remote Control Operation"

Thermostat Does Not

Work

The pilot light has gone out

The ON/OFF switch is turned to "OFF"

The thermostat is set too high

See "Starting the Pilot Light"

Turn the ON/OFF switch to "ON"

See "Thermostat Operation"

Heater Will Not

Distribute Heat

The heater is unplugged

The heater is not up to temperature

Plug the heater in.

See "Operating Your Heater"

Pilot Goes Out Once A

Month Or More

The gas supply has not been shut off

The vent is experiencing a cold air blockage or a negative
pressure situation exists in the home

Keep the gas supply turned on

This is a necessary safety feature that
disables the heater if a down draft occurs.
If this problem is persistent the vent may
need to be improved or changes may need
to be done to remove the negative pressure
inside the home - see your dealer for
details

Flame (and Pilot) Goes

Out 10 to 25
Minutes After
Starting

The vent is experiencing a cold air blockage or a negative
pressure situation exists in the home

This is a necessary safety feature. First try
restarting the heater. If it works correctly,
a cold air blockage occurred and the vent
just needed to be heated sufficiently. If
this problem is persistent the vent may
need to be improved or changes may need
to be done to remove the negative pressure
inside the home - see your dealer for
details

Flames Are Too Blue

The heater has just been started

This is normal - see "Operating Your
Heater"

Flames Are Orange

With Dirty Smoke

Something may be placed against the heater

See "How this Heater Works"

Flames Are Too Short

(Under 6")

The flame height may be turned too low

Something may be placed against the heater

Turn the flame height to "HI" -
See "Operating Your Heater"

See "How this Heater Works"

Thin Layer of Soot

Covers the Glass

The logs are placed incorrectly

See "Installing the Logs and Ember Strip"

This manual is related to the following products: