O
PTIONAL
E
QUIPMENT
(C
ONTINUED
)
P
AGE
41
45
°
Flue Adapter
(Part # 98900118)
The 45
°
flue adapter is designed for insert installations requiring a more flexible flue outlet.
1
Install the flue adapter prior to inserting the insert into the fireplace.
2
Use a phillips-head screwdriver to unscrew the two screws holding the spill switch bracket in
place. Place the screws and bracket, with wires still attached, aside.
3
Unscrew the seven screws holding the draft hood in place. Lift up slightly on the air
deflector and slide the draft hood towards the rear of the heater until it comes free. Discard
the old draft hood.
4
With the air deflector lifted up slightly, slide the 45
°
flue adapter into place. Make sure the
flue adapter fits underneath the air deflector. Replace the seven screws to secure the flue
adapter.
5
Attach the spill switch bracket to the 45
°
flue adapter with the two screws removed in step 2.
1/4" Nutdriver
Unscrew the seven
screws to remove the
draft hood.
NOTE: Lift the air deflector slightly
and slide the draft hood towards
the rear to remove.
When installing the 45¡ flue
adapter, lift the air deflector and
slide the flue adapter underneath
the air deflector.
Draft Hood
Air Deflector
Once installed, the vent is located
1-1/4" forward and 18-1/4" above
the rear edge of the insert.
18-1/4"
1-1/4"
Remove the spill switch bracket
by removing the two attachment
screws (keep the two wires
attached).
45¡ Flue
Adapter
Phillips
Screwdriver
Attach the bracket to
the 45¡ Flue Adapter.