Functional Description

COMX-P40x0 ENP2 Installation and Use (6806800R95C)

75

4.7

Thermal Management

The COMX-P40x0 ENP2 module provides a thermal management strategy. This includes CPU
junction temperature monitoring as shown in the following figure:

A thermal diode is integrated in the P40x0, which connects to a thermal sensor ADT7411. The
CPU can get the junction temperature via I2C.

When the junction temperature reaches105

o

C, the ADT7411 drives INT# low, to indicate an

interrupt to the CPU. The red LED D17 shows the interrupt status.

Figure 4-4

Module Thermal Management

LED

Definition

Status

Description

D17

INT# signal is active

ON

The CPU temperature has
reached 105

o

C

OFF

Normal status