Environmental and Power Requirements

2.1.1

Environmental Requirements

The following environmental requirements must not be exceeded.

The following table provides the environmental requirements for the module.

Thermal Requirements

A standard passive heat sink can be provided by Artesyn; 12 CFM system airflow volume (at
71

o

C) is needed for the heat sink to keep sufficient cooling to the module. Contact your

Artesyn sales representative for detailed thermal information.

Operating temperature refers to the temperature of the air circulating around the module
and not the component temperature.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

-40°C to +71°C

-50°C to +100°C

Humidity

to 100% RH

to 100

% RH

Vibration Sine (10mins/axis)

5 G, 15 to 2000Hz

Vibration Random (1hr/axis)

0.04 g

2

/Hz, 15 to 2000 Hz

(8GRMS)

Shock

30g/11 mS(half sine)

Altitude