Clock Distribution

The COMX-P4080 needs several kinds of single-ended and different clocks for booting up and
normal operation. The clock distribution list is illustrated below.

The frequency of the three SerDes banks’ reference clocks can be set from 100 MHz to 125
MHz using the S1 switch.

Figure 4-5

COMX-P4080 Clock Distribution

Table 4-2 SerDes Clock Configuration by S1 Switch

SerDes Bank 1 Reference Clock SerDes Bank 2 Reference Clock SerDes Bank 3 Reference Clock

S1.2=ON, 125MHz

S1.3=ON, 100MHz

S1.4=ON, 100MHz

S1.2=OFF, 100MHz

S1.3=OFF, 125MHz

S1.4=OFF, 125MHz

Default:100MHz

Default:125MHz

Default:125MHz