4 s2 switch, Table 3-4, S2 switch settings – Artesyn COMX-P4080 Installation and Use (August 2014) User Manual
Page 52: Controls, leds, and connectors
![background image](https://www.manualsdir.com/files/772497/content/doc052.png)
Controls, LEDs, and Connectors
COMX-P4080 COM Express Module Installation and Use (6806800L20C)
52
3.2.4
S2 Switch
Table 3-4 S2 Switch Settings
S2.1~S2.5
RCW Source
OFF,ON,ON,OFF,ON
I2C1 normal addressing (supports ROMs up to 256 bytes)
OFF,ON,ON,OFF,OFF
I2C1 extended addressing
OFF,ON,OFF,OFF,ON
SPI 16-bit addressing
OFF,ON,OFF,OFF,OFF
SPI 24-bit addressing
OFF,OFF,ON,OFF,ON
eLBC FCM (NAND flash, 8-bit small page)
OFF,OFF,ON,OFF,OFF
eLBC FCM (NAND flash, 8-bit large page)
OFF,OFF,OFF,OFF,OFF
eLBC GPCM (NOR flash, 16-bit)
ON,X,X,X,X
Hard-coded RCW options
ON,ON,ON,OFF,ON
Large page NAND flash as boot location; USB2 and dual 4-pin UART
enabled; Platform ratio of 8:1; Core PLL ratio of 14:1
ON,ON,ON,OFF,OFF
Large page NAND flash as boot location; RGMII FM1 MAC1 and
dual 4-pin UART enabled; Platform ratio of 8:1; Core PLL ratio of
14:1
ON,ON,ON,ON,ON
16-bit NOR flash as boot location; USB2 and dual 4-pin UART
enabled; Platform ratio of 8:1; Core PLL ratio of 14:1
ON,ON,ON,ON,OFF
16-bit NOR flash as boot location; RGMII FM1 MAC1 and dual 4-pin
UART enabled; Platform ratio of 8:1; Core PLL ratio of 14:1
ON,ON,OFF,OFF,OFF
Three (x2, x2, x4) PCI-E @ 2.5G, 100 MHz ref clk, all agent mode; all
cores in boot hold-off; dual 4-pin UART enabled
ON,ON,OFF,OFF,ON
Two (x4, x4) SRIO @ 2.5G, 100 MHz ref clk, all agent mode; all cores
in boot hold-off; dual 4-pin UARTs enabled
ON,ON,OFF,ON,OFF
Large page NAND flash as boot location; USB2 and dual 4-pin
UARTs enabled; Platform ratio of 6:1; Core PLL ratio of 10:1
ON,ON,OFF,ON,ON
Large page NAND flash as boot location; RGMII FM1 MAC1 and
dual 4-pin UARTs enabled; Platform ratio of 6:1; Core PLL ratio of
10:1
ON,OFF,ON,OFF,OFF
16-bit NOR flash as boot location; RGMII FM1 MAC1 and dual 4-pin
UARTs enabled; Platform ratio of 6:1; Core PLL ratio of 10:1