Controls, LEDs, and Connectors

COMX-P4080 COM Express Module Installation and Use (6806800L20C)

51

3.2.3

S1 Switch

COMX-P4080 has a bug which prevents SerDes Bank 1 and SerDes Bank 2 from using the same
reference clock frequency.

For the SerDes configuration options 1, 2, 4, and 6, set sd_refclk1 as 100 MHz and sd_refclk2
as 125 MHz. For configuration options 3 and 5, set sd_refclk1 as 125 MHz and sd_refclk2 as 100
MHz.

Table 3-3 S1 Switch Settings

S1 Bit

Function

1

Boot mode selection

ON: Secure boot mode

OFF: Non-secure mode (Default)

2

Reference clock frequency of bank 1

ON: 125 MHz

OFF: 100 MHz (Default)

3

Reference clock frequency of bank 2

ON: 100 MHz

OFF: 125 MHz (Default)

4

Reference clock frequency of bank 3

ON: 100 MHz

OFF: 125 MHz (Default)

5

RCW source selection between NOR
and NAND flash

ON: NAND flash

OFF: NOR flash (Default)

6

Not used

7

GPI for debugging

ON: 1

OFF: 0 (Default)

8

Local bus on carrier

ON: Enabled

OFF: Disabled (Default)