BSP Operations

COMX-P4080 COM Express Module Installation and Use (6806800L20C)

112

An exception for frame manager network ports is when the nfsboot, which is the network port
for mounting NFS, remains "ethX" and will not be renamed to "fmY-gbZ" in Linux because the
udev cannot rename the device that is currently busy.

For network ports of PRO/1000, the port name is always "ethX".

In order to use SGMII/XAUI network ports of the frame managers, ten U-Boot network
environment variables for MAC addresses must be set.

7.19 Boot

COMX-P4080 provides the following boot methods:

RAMboot

NORboot

NANDboot

Port 4 (FM2@TGEC1) (XAUI) is named as fm2-10g

=> setnev ethaddr

=> setenv eth1addr 00:01:af:12:23:92

=> setenv eth2addr 00:01:af:12:23:93

=> setenv eth3addr 00:01:af:12:23:94

=> setenv eth4addr 00:01:af:12:23:95

=> setenv eth5addr 00:01:af:12:23:96

=> setenv eth6addr 00:01:af:12:23:97

=> setenv eth7addr 00:01:af:12:23:98

=> setenv eth8addr 00:01:af:12:23:99

=> setenv eth9addr 00:01:af:12:23:9a

=>saveenv