DLM-E 3kW & 4kW Series Power Supplies

Advanced Operation

Figure 4–1. J3 Connector

Pin No.

Function

Pin No.

Function

1

Remote Output Enable
1 = Enable, 0 = Disable

14

Remote Shutdown Input (+). Positive or
negative true logic selection with S1

2

Remote Shutdown Return (–)

15

+5 VDC Aux. Output

3

Remote OVP Programming Input

16

1 mA current source for OVP
Programming

4

Remote Programming Indicator
1 = Remote, 0 = Local

17

OVP Status Indicator
1 = OVP Shutdown, 0 = Normal

5

Operating Mode Indicator
1 = Volt mode, 0 = Current mode

18

Overtemp Shutdown Indicator
1 = OTP Shutdown, 0 = Normal

6

Status Indicator Return (–)

19

DC Voltage Monitor Output

7

Current Monitor Output

20

Remote/Local Voltage Control Select

8

N/C – for all models , except

16V, 22V models – Fault signal,
Active High, 10mA current source

21

1 mA current source for Voltage
Programming

9

Voltage Programming Input

22

1 mA current source for Current
Programming

10

Current Programming Input

23

Remote/Local Current Control Select

11 N/C

24 N/C

12

Programming/Monitor Return (–)

25

N/C

13 N/C

Table 4–1. J3 Connector – Program, Control, and Monitor Description

(D–subminiature 25–Pin Female)

4.2.2

Rear Panel DIP Switch

Switch S1 is located on the main printed circuit board and is able to be changed through the
rear panel of the power supply. The J3 connector is located on the unit's rear panel. See
Section 4.2.3 Resetting Rear Panel DIP Switch Settings and Section 4.2.4 Making J3
Connections
.