beautypg.com

Figure 3–1. operating modes -2 – AMETEK DLM Series User Manual

Page 40

background image

Basic Operation

DLM-E 3kW & 4kW Series Power Supplies

Figure 3–1 provides a graphical representation of the relationships between these variables.

Constant Voltage Mode Operation

The power supply will operate in constant voltage mode whenever the load current I

L

is less

than the current limit setting I

SET

, or: I

L

< I

SET

(Note: I

L

= V

SET

/ R

L

)

In constant voltage mode, the power supply maintains the output voltage at the selected value
(V

SET

) while the load current I

L

varies with the load requirements.

Constant Current Mode Operation

The power supply will operate in constant current mode whenever the load resistance is low
enough that the load current I

L

is greater than the current limit setting I

SET

, or: I

L

> I

SET

In constant current mode, the power supply maintains the output current at the selected value
(I

SET

) while the load voltage varies with the load requirements.

Figure 3–1. Operating Modes

Automatic Mode Crossover

This feature allows the power supply to automatically switch operating modes in response to
changing load requirements. If, for instance, the power supply was operating in Constant
Voltage Mode (I

L

< I

SET

), and the load changed so that the load current (I

L

) became greater

than the current limit setting (I

SET

), the power supply would automatically switch into Constant

Current Mode. If the additional load was subsequently removed so that the load current was
again less than the current limit setting, the supply would automatically return to Constant
Voltage Mode.

3-2

M362000-01 Rev E