Features and Specifications

DLM-E 3kW & 4kW Series Power Supplies

1-4

M362000-01 Rev E

1.4.2

4 kW DLM–E Electrical Specifications

9

Model 5–450

8–450

16–250 22-180 32–125 40–100 60–66 80–50 150–26 300–13 600–6.6

Output Ratings:

Output Voltage
Output Current
Output Power


0–5V
0–450A
2250W


0–8V
0–450A
3600W


0–16V
0–250A
4000W


0-22V
0-180A
4000W


0–32V
0–125A
4000W


0–40V
0–100A
4000W


0–60V
0–66A
3960W


0–80V
0–50A
4000W


0–150V
0–26A
3900W


0–300V
0–13A
3900W


0–600V
0–6.6A
3960W

Line Regulation:

10

Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)


5 mV
450 mA


6 mV
450 mA


10 mV
250 mA


13 mV
180mA


18 mV
125 mA


22 mV
100 mA


32 mV
66 mA


42 mV
50 mA


77 mV
26 mA


152 mV
13 mA


302 mV
7 mA

Load Regulation:

11

Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)


5 mV
450 mA


6 mV
450 mA


10 mV
250 mA


13 mV
180mA


18 mV
125 mA


22 mV
100 mA


32mV
66 mA


42 mV
50 mA


77 mV
26 mA


152 mV
13 mA


302 mV
7 mA

Meter Accuracy:

Voltage (0.5% Vmax+1count)
Current (0.75% Imax+1count)


0.04V
5A


0.05V
5A


0.09V
3A


0.2V
3A


0.3V
1A


0.3V
0.9A


0.4V
0.6A


0.5V
0.5A


0.9V
0.3A


1.6V
0.11A


3.1V
0.06A

Preview Accuracy

Voltage (0.5% Vmax+1 count)
Current (1.0% Imax+1 count)


0.04V
6A


0.05V
6A


0.09V
4A


0.2V
3A


0.3V
1.4A


0.3V
1.1A


0.4V
0.8A


0.5V
0.6A


0.9V
0.4A


3V
0.14A


4V
0.08A

OVP Adjustment Range
(6% to 110% Vmax)

0.3–
5.5V

0.4–
8.8V

0.8–
17.6V

1.1-
24.2V

1.6–35V 2–44V 3–66V 4–88V

7.5–
165V

15–
330V

30–
660V

Output Noise and Ripple (V)

RMS
p–p (20 Hz–20 MHz)


12 mV
100
mV

12


12 mV
100
mV

12


10 mV
100
mV

12


10 mV
100
mV

12


10 mV
100
mV

12


10 mV
100
mV

12


15 mV
100 mV


15 mV
120 mV


30 mV
100 mV


60 mV
150 mV


100 mV
300 mV

Stability:

13, 14

Voltage (0.05% of Vmax)
Current (0.05% of Imax)


3 mV
225 mA


4 mV
225 mA


8 mV
125 mA


11 mV
90 mA


16 mV
63 mA


20 mV
50 mA


30 mV
33 mA


40 mV
25 mA


75 mV
13 mA


150 mV
6.5 mA


300 mV
3.3 mA

Temperature Coefficient:

15

Voltage (0.02% of Vmax)
Current (0.03% of Imax)


1 mV
135 mA


1.6 mV
135 mA


3.2 mV
75 mA


4.4 mV
54 mA


6 mV
38 mA


8 mV
30 mA


12 mV
19.8 mA


16 mV
15 mA


30 mV
7.8 mA


60 mV
3.9 mA


120 mV
2.0 mA

Maximum Remote Sense
Line Drop Compensation per line

16

2V 2V 2V 2V 5V 5V 5V 5V 5V 5V 5V

9.

Specifications are warranted over a temperature range of 0–50°C with default local sensing.
From 50–70°C, derate output 2% per °C.
From 40–70°C, derate output 2% per °C below 190 VAC with single or three–phase inputs.

10.

For input voltage variation over the AC input voltage range, with constant rated load.

11.

For 0–100% load variation, with constant nominal line voltage.

12.

Typical P–P noise and ripple is 50 mV.

13.

Maximum drift over 8 hours with constant line, load, and temperature, after 15 minute warm–up (30 minute warm–up
for 5V, 8V, and 16V models).

14.

Current accuracy for 5V, 8V, and 16V models is 1% typical.

15.

Change in output per °C change in ambient temperature, with constant line and load.

16.

Line drop subtracts from the maximum available output voltage at full rated power.