DLM-E 3kW & 4kW Series Power Supplies

Features and Specifications

M362000-01 Rev E

1-5

1.4.3

Additional Specifications

AC Input:

Output

Power

Nominal Input

Voltage

Input

Option

Input Range

(47–63 Hz)

Input Current

Maximum

17

Input Power

Factor

18

3 kW

19

230 VAC

Single–Phase

Std

180–264 VAC L–L

21A RMS

0.98

3 kW

19

208 VAC

Three–Phase

Std

180–264 VAC L–L

12A RMS

0.95

4 kW

208 VAC

Three–Phase

Std

180–264 VAC L–L

15A RMS

0.95

4 kW

380/400/415 VAC

Three–Phase

M1

345–455 VAC L–L

8.5A RMS

0.95

4 kW

480 VAC

Three–Phase

M2

432–528 VAC L–L

6.5A RMS

0.95

17.

Maximum input current measured at low AC line and maximum output power.

18.

Power factor measured at nominal line, maximum output power.

19.

The 3 kW DLM–E is designed to operate without derating to the output power level with either
a single–phase or three–phase AC input voltage without any internal jumper changes.

Efficiency: 5 and 8 VDC models – 82% typical, 16–600 VDC models – 87% typical

Altitude: 2000M (6562 Ft.)

Operating Temperature Range: 0 to 50°C

Storage Temperature Range: –40 to +85°C

Humidity Range: 0 to 80% Non–condensing

Time Delay from power on until output is stable: 10 seconds maximum

Voltage Mode Transient Response Time: 1 ms recovery to 1% band for 30% step load
change from 70% to 100% or 100% to 70%

Remote Start/Stop and Interlock: TTL compatible input, Contact Closure, 5–24 VDC.

Switching Frequency: Nominal 32 kHz (64 kHz output ripple)

Float Voltage: Negative output terminal may be biased to 150 VDC relative to chassis.

For models 16V, 22V output terminal may be biased to 600 VDC relative to
chassis.

Remote Analog Programming (Full Scale Input): Scales are selectable through rear panel.

Parameter

Resistance Voltage

Voltage

5 k

Ω

5V, 10V

Current

5 k

Ω

5V, 10V

OVP

5 k

Ω

5V, 10V

Analog Programming Accuracy: 1% of rated output for voltage programming, 5% of rated
output for resistance programming, 2% of rated output voltage for OVP.