DLM-E 3kW & 4kW Series Power Supplies

Features and Specifications

M362000-01 Rev E

1-3

1.4 Specifications

1.4.1

3 kW DLM–E Electrical Specifications

1

Model 5–350

8–350

16–185 32–95 40–75 60–50 80–37 150–20 300–10 600–5

Output Ratings:

Output Voltage
Output Current
Output Power


0–5V
0–350A
1750W


0–8V
0–350A
2800W


0–16V
0–185A
2960W


0–32V
0–95A
3040W


0–40V
0–75A
3000W


0–60V
0–50A
3000W


0–80V
0–37A
2960W


0–150V
0–20A
3000W


0–300V
0–10A
3000W


0–600V
0–5A
3000W

Line Regulation:

2

Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)


5 mV
350 mA


6 mV
350 mA


10 mV
185 mA


18 mV
95 mA


22 mV
75 mA


32 mV
50 mA


42 mV
37 mA


77 mV
20 mA


152 mV
10 mA


302 mV
5 mA

Load Regulation:

3

Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)


5 mV
350 mA


6 mV
350 mA


10 mV
185 mA


18 mV
95 mA


22 mV
75 mA


32mV
50 mA


42 mV
37 mA


77 mV
20 mA


152 mV
10 mA


302 mV
5 mA

Meter Accuracy:

Voltage (0.5% Vmax+1count)
Current (1.0% Imax+1count)


0.04V
4A


0.05V
4A


0.09V
3A


0.3V
0.8A


0.3V
0.7A


0.4V
0.5A


0.5V
0.4A


0.9V
0.3A


3V
0.09A


4V
0.05A

Preview Accuracy

Voltage (0.5% Vmax+1 count)
Current (1.0% Imax+1 count)


0.04V
6A


0.05V
5A


0.09V
3A


0.3V
1.1A


0.3V
0.9A


0.4V
0.6A


0.5V
0.5A


0.9V
0.3A


3V
0.11A


4V
0.06A

OVP Adjustment Range
(6% to 110% Vmax)

0.3–5.5V 0.4–8.8V

0.8–
17.6V

1.6–35V 2–44V 3–66V 4–88V

7.5–
165V

15–330V 30–660V

Output Noise and Ripple (V)

RMS
p–p (20 Hz–20 MHz)


12 mV
100 mV

4


12 mV
100 mV

4


10 mV
100 mV

4


10 mV
100 mV

4


10 mV
100 mV

4


15 mV
100 mV


15 mV
120 mV


30 mV
200 mV


60 mV
300 mV


100 mV
500 mV

Stability:

5, 6

Voltage (0.05% of Vmax)
Current (0.05% of Imax)


3 mV
175 mA


4 mV
175 mA


8 mV
93 mA


16 mV
48 mA


20 mV
38 mA


30 mV
25 mA


40 mV
19 mA


75 mV
10 mA


150 mV
5 mA


300 mV
2.5 mA

Temperature Coefficient:

7

Voltage (0.02% of Vmax)
Current (0.03% of Imax)


1 mV
105 mA


1.6 mV
105 mA


3.2 mV
55 mA


6 mV
30 mA


8 mV
23 mA


12 mV
15 mA


16 mV
12 mA


30 mV
6 mA


60 mV
3 mA


120 mV
1.5 mA

Maximum Remote Sense
Line Drop Compensation per line

8

2V 2V 2V 5V 5V 5V 5V 5V 5V 5V

1.

Specifications are warranted over a temperature range of 0–50°C with default local sensing.
From 50–70°C, derate output 2% per °C.
From 40–70°C, derate output 2% per °C below 190 VAC with single or three–phase inputs.

2.

For input voltage variation over the AC input voltage range, with constant rated load.

3.

For 0–100% load variation, with constant nominal line voltage.

4.

Typical P–P noise and ripple is 50 mV.

5.

Maximum drift over 8 hours with constant line, load, and temperature, after 15 minute warm–up (30 minute warm–up
for 5V, 8V, and 16V models).

6.

Current accuracy for 5V, 8V, and 16V models is 1% typical.

7.

Change in output per °C change in ambient temperature, with constant line and load.

8.

Line drop subtracts from the maximum available output voltage at full rated power.