DLM-E 3kW & 4kW Series Power Supplies
Features and Specifications
M362000-01 Rev E
1-3
1.4 Specifications
1.4.1
3 kW DLM–E Electrical Specifications
1
Model 5–350
8–350
16–185 32–95 40–75 60–50 80–37 150–20 300–10 600–5
Output Ratings:
Output Voltage
Output Current
Output Power
0–5V
0–350A
1750W
0–8V
0–350A
2800W
0–16V
0–185A
2960W
0–32V
0–95A
3040W
0–40V
0–75A
3000W
0–60V
0–50A
3000W
0–80V
0–37A
2960W
0–150V
0–20A
3000W
0–300V
0–10A
3000W
0–600V
0–5A
3000W
Line Regulation:
2
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
5 mV
350 mA
6 mV
350 mA
10 mV
185 mA
18 mV
95 mA
22 mV
75 mA
32 mV
50 mA
42 mV
37 mA
77 mV
20 mA
152 mV
10 mA
302 mV
5 mA
Load Regulation:
3
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
5 mV
350 mA
6 mV
350 mA
10 mV
185 mA
18 mV
95 mA
22 mV
75 mA
32mV
50 mA
42 mV
37 mA
77 mV
20 mA
152 mV
10 mA
302 mV
5 mA
Meter Accuracy:
Voltage (0.5% Vmax+1count)
Current (1.0% Imax+1count)
0.04V
4A
0.05V
4A
0.09V
3A
0.3V
0.8A
0.3V
0.7A
0.4V
0.5A
0.5V
0.4A
0.9V
0.3A
3V
0.09A
4V
0.05A
Preview Accuracy
Voltage (0.5% Vmax+1 count)
Current (1.0% Imax+1 count)
0.04V
6A
0.05V
5A
0.09V
3A
0.3V
1.1A
0.3V
0.9A
0.4V
0.6A
0.5V
0.5A
0.9V
0.3A
3V
0.11A
4V
0.06A
OVP Adjustment Range
(6% to 110% Vmax)
0.3–5.5V 0.4–8.8V
0.8–
17.6V
1.6–35V 2–44V 3–66V 4–88V
7.5–
165V
15–330V 30–660V
Output Noise and Ripple (V)
RMS
p–p (20 Hz–20 MHz)
12 mV
100 mV
4
12 mV
100 mV
4
10 mV
100 mV
4
10 mV
100 mV
4
10 mV
100 mV
4
15 mV
100 mV
15 mV
120 mV
30 mV
200 mV
60 mV
300 mV
100 mV
500 mV
Stability:
5, 6
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
3 mV
175 mA
4 mV
175 mA
8 mV
93 mA
16 mV
48 mA
20 mV
38 mA
30 mV
25 mA
40 mV
19 mA
75 mV
10 mA
150 mV
5 mA
300 mV
2.5 mA
Temperature Coefficient:
7
Voltage (0.02% of Vmax)
Current (0.03% of Imax)
1 mV
105 mA
1.6 mV
105 mA
3.2 mV
55 mA
6 mV
30 mA
8 mV
23 mA
12 mV
15 mA
16 mV
12 mA
30 mV
6 mA
60 mV
3 mA
120 mV
1.5 mA
Maximum Remote Sense
Line Drop Compensation per line
8
2V 2V 2V 5V 5V 5V 5V 5V 5V 5V
1.
Specifications are warranted over a temperature range of 0–50°C with default local sensing.
From 50–70°C, derate output 2% per °C.
From 40–70°C, derate output 2% per °C below 190 VAC with single or three–phase inputs.
2.
For input voltage variation over the AC input voltage range, with constant rated load.
3.
For 0–100% load variation, with constant nominal line voltage.
4.
Typical P–P noise and ripple is 50 mV.
5.
Maximum drift over 8 hours with constant line, load, and temperature, after 15 minute warm–up (30 minute warm–up
for 5V, 8V, and 16V models).
6.
Current accuracy for 5V, 8V, and 16V models is 1% typical.
7.
Change in output per °C change in ambient temperature, with constant line and load.
8.
Line drop subtracts from the maximum available output voltage at full rated power.