Adept EX SmartContoller User Manual
Page 37
Chapter 3: Operation
Table 3-6. Contacts Provided by the XUSR Connector
Pin
Pairs
Description
Comments
Voltage-Free Contacts Provided by Customer
1, 14
User E-Stop CH 1 (mushroom push-
button, safety gates, etc.)
N/C contacts, Shorted if NOT Used
2, 15
User E-Stop CH 2 (same as pins
1, 14)
N/C contacts, Shorted if NOT Used
3, 16
Line E-Stop (used for other robot or
assembly line E-Stop inter-
connection. Does not affect E-Stop
indication (pins 7, 20))
N/C contacts, Shorted if NOT Used
4, 17
Line E-Stop (same as pins 3, 16)
N/C contacts, Shorted if NOT Used
5, 18
Muted safety gate CH 1 (causes E-
Stop in Automatic mode only)
N/C contacts, Shorted if NOT Used
6, 19
Muted Safety Gate CH 2 (same as
pins 5, 18)
N/C contacts, Shorted if NOT Used
Voltage-Free Contacts provided by Adept
7, 20
E-Stop indication CH 1
Contacts are closed when Front Panel, pend-
ant, and customer E-Stops are not tripped
8, 21
E-Stop indication CH 2 (same as
pins 7, 20)
Contacts are closed when Front Panel, pend-
ant, and customer E-Stops are not tripped
9, 22
Manual/Automatic indication CH 1
Contacts are closed in Automatic mode
10, 23
Manual/Automatic indication CH 2
Contacts are closed in Automatic mode
11, 12,
13, 24,
25
No connection
Table 3-7. Contacts Provided by the XFP Connector
Pin
Pairs
Description
Requirements for User-
Supplied Front Panel
Voltage-Free Contacts Provided by Customer
1, 9
Front Panel E-Stop CH 1
User must supply N/C con-
tacts
2, 10
Front Panel E-Stop CH 2
User must supply N/C con-
tacts
3, 11
Remote Manual/Automatic switch CH 1.
Manual = Open Automatic = Closed
Optional - jumper closed for
Auto Mode-only operation
Adept SmartController EX User’s Guide, Rev. B