The Z8051 OCD In-System Programmer

Z8051 On-Chip Debugger and In-System Programmer

User Manual

86

3. The next dialog box, shown in Figure 96, prompts you to enter a path or navigate to

the directory in which the

.inf

file was installed. Depending on the type of computer

you use (32- bit or 64-bit), use the

Browse

button to navigate to one of the following

paths and click the

Next

button, leaving all other selections at their default settings.

On 32-bit machines, use the following path:

\Z8051_\device drivers\OCD USB\x32

On 64-bit machines, use the following path:

\Z8051_\device drivers\OCD USB\x64

On some installations, the Found New Hardware screen shown in Figure 95 may also dis-
play the text string,

Zilog Z8051 USB OCD - No Firmware

. This occurrence is normal

and can be disregarded.

Figure 96. The Found New Hardware Wizard’s Browse Screen