Connection Setting
•
et
•
input the static IP address you set in
the DUT here.
WAN Link Type: Choose the WAN connection type for
DUT testing. Three WAN Link Types are available:
DHCP, Static IP, and PPPoE. The WAN Link Type s
here must be the same with the setting of the DUT.
DUT WAN Static IP: If the WAN Link Type is set as
Static IP, please
•
ttempting to establish connection
•
put the gateway IP address you set
Connection Wait Timeout: This function sets the
duration of time for a
with DHCP server.
WAN Gateway IP: If the WAN Link Type is set as
Static IP, please in
in the DUT here.
•
Ts’
match DUT vender’s
•
CP Process if Valid: Disable or enable DHCP
server.
Check Vender ID: Enable this function to check DU
MAC address and see if they
designated MAC address.
Skip DH
•
If Check Vender ID is enabled, please input the vender’s designated MAC address here for
Vendor MAC:
comparisons.
VLAN Setting
•
LAN VLAN Tag: Add VLAN tags to all LAN packets.
•
LAN VLAN ID: VLAN ID for LAN.
•
WAN VLAN Tag: Add VLAN tags to all WAN packets
•
WAN VLAN ID: VLAN ID for WAN.
Test Traffic
•
Packet Length: Length of testing packets.
•
ount of time
Delay Time After Learning: When enabled,
NuStreams-P6GW will halt for the set am
after performing network learning.
•
Test Time: The duration of time for DUT test.
•
Delay Before Report: When enabled,
NuStreams-P6GW will halt for the set amount of time
before report.
•
Test Delay: When enabled, NuStreams-P6GW will h
for the set amount of time before starting DUT test.
alt
•
WAN to LAN Utilization (%): The traffic flow ratio from
WAN to LAN, presented in percentage (1~100).
•
Flow Control: W
transmitting rate w
hen Flow Control is enabled, the
ill drop if traffic overflow occurs.
•
o from
LAN to WAN Utilization (%): The traffic flow rati
LAN to WAN, presented in percentage (1~100).
Pass/Fail Criteria
•
Loss Tolerance (pkts): The acceptable number of lost
n data transmitting during tests (0~9999).
•
rance (pkts): The acceptable number of
exc
packets in data transmitting during tests
packets i
Excess Tole
ess
(0~9999).
Apply Run
• Click this button to apply all the settings you’ve made and save the settings to NuStreams-P6GW.
* Note: It is recommended to perform WLAN tests in a shielding room.
Note: When WLAN is enabled, NuStreams-P6GW will attempt to connect with the first WAP
(Wireless Access Point) that appears in it
*
s SSID list. If that WAP is encrypted, NuStreams-P6GW
will apply the password you input here.