Examples: (These are hypothetical examples.)
Suppose you forget what you stored in memory filter 3. You position the
controls as follows:

Control Position

Meaning

Memory button:

in

select memory filters

Filters switch:

3 (2BP)

memory filter 3

Manual Notch button:

out

manual notch off

Auto Notch button:

in

auto notch on

Noise Reduction control:

midrange

reduction level 5

Noise Reduction button:

in

noise reduction on

Auto Notch aggressiveness: jumper-programmed

level 3


Then release the DSP button out, press and release the Program button, and
the VEC-884 sends:

BP CF 1025 BW 350 AN 3 NR 5

You now know that in memory position 3 you have a narrow band-pass filter
with a bandwidth of 350 Hz and center frequency of 1025 Hz. The unit also
sent your current settings for notch and noise reduction. Now suppose you
try memory filter 6.

Turn the Filters switch to 6 (RTTY).
Press the Program button and the VEC-884 sends:

RTTY CF 1360 BW 279 NR 5

In this position, you have saved a jumper-programmed RTTY filter with the
center frequency of 1360 Hz and a bandwidth of 279 Hz. These are the
settings for European RTTY. Notice that there is nothing sent for auto notch
because it is disabled in the RTTY filter.

These are examples of the individual filter settings:

LR/HR

High-pass/low-pass (LR < HR):

LRHR 2000-3400

Band-stop filter (LR > HR):

LRHR 0-1400 2200-3900

All-pass filter (LR = HR):

LRHR 0-3900

BP

Normal

filter:

BP CF 1500 BW 2100

Limited filter:*

BP CF 675 BW 1350