• Shut down system automatically when the system’s internal temperature

is over 80C.

• VMC 1000 will automatically shut down 5 minutes after the duration

of low battery voltage is over 60 sec. User can detect this situation via
software.

• If the ignition is off and the system is still on after 3 minutes, VMC 1000

will shut down automatically.

• If the ignition is off, the user can detect this status via the software.

• If the ignition is turned on again and the power-off delay is in progress,

VMC 1000 will cancel the delay function and will continue to operate
normally.

• If the ignition is turned on again and the power-off delay ended, VMC 1000

will shut down completely will power-on again automatically.

• If the ignition is turned off again and power-on delay is in progress, VMC

1000 will cancel the delay and stay in power-off status.

• If the ignition is turned off again and the power-on delay ended (in BIOS

process), VMC 1000 will shut down immediately.

• If VMC 1000 is off, only below 10mA is used.