beautypg.com

Hardware specifications – NEXCOM VMC 1000 User Manual

Page 17

background image

Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved

4

VMC 1000 User Manual

Chapter 1: Product Introduction

Hardware Specifications

Dimensions
• 185.4 mm (W) x 141.4 mm (D) x 50.42 mm (H) (7.3” x 5.57” x 1.99”)
• 1 Kg (2.20 Lb)

Construction
• Plastic case with aluminum die casting heatsink
• Compliant with IP54

Environment
• Operating temperatures:

Ambient with air:
-20°C to 50°C

• Storage temperatures: -30°C to 80°C

• Relative humidity: 10% to 90% (Non-condensing)
• Vibration (random): 2g@5~500 Hz
• Vibration

Operating: MIL-STD-810F, Method 514.5, Category 20, Ground
Vehicle – Highway Truck
Storage: MIL-STD-810F, Method 514.5, Category 24, Integrity Test

• Shock (with SSD)

- Operating: MIL-STD-810F, Method 516.5, Procedure I, Trucks and

semi-trailers=20g

- Crash Hazard: MIL-STD-810F, Method 516.5, Procedure V, Ground

equipment=75g

Certifications

• CE approval
• FCC Class B
• e13 Mark

Power Management

• Power-on delay time is selectable by BIOS to disable and enable in 10sec

/ 30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.

• Power-off delay time is selectable by BIOS to disable and enable in 20sec

/ 1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.

• S4 suspend mode
• Ignition On/Off status detectable by SW
• Low battery status detectable by SW
• Ignition enable/disable is jumper selectable