Contr 03, 0 h2, 007 d1as – CIRCUTOR DISPENSER Series User Manual
Page 87

5.4.- DISPLAY SCREENS
After the contract has been loaded in the
Dispenser, the following screens can be viewed, as
shown in
The unit will scroll the different screens every 7 seconds. You can also scroll the screens by
clicking on
.
Table 33: Display screens�
Screens
Contr 03
L1
Type of active contract: 01, 02, 03 or 04.
The relay will be opened if the balance is used up. “EXPIRED” will appear on
the screen:
00000002
Contr Expired
L1
23.12.14
L1
1120
Current date and time
000026.40
L1
En
kWh
Imported energy, energy consumed by the user (kWh, with 2 decimal places)
000000.02
L1
En
kWh
Exported energy, energy generated by the user (kWh, with 2 decimal places)
00.00
L1
PotEn
kW
Instantaneous power, energy currently being consumed (kW, with 2 decimal
places).
000000. 5
L1
FrEC
50.0 H2
Frequency (Hz, with 1 decimal place)
007 d1As
L1
Fin
Contract period, remaining validity period of the contract before it expires.
Type 2 and 3 contracts show the contract period calculated by the
Dispenser
according to the current consumption levels.
87
Instruction Manual
Dispenser Universal System