5�6�3�- POWER CUT

Note: This menu is displayed if the wire cover sensor has been activated.

L1

CortE

Figure 132:Power cut

The general relay of the

Dispenser can be disconnected in this menu. To do so, long press the

button.

The unit opens the general relay and displays the screen shown in

Figure 133

permanently.

L1

rEArME

CortE

Figure 133:Closing Process Complete Screen�

Long press the

button to rearm the general relay.

5.7.- RS-485 COMMUNICATIONS

The

Dispensers feature an RS-485 communications port.

The unit has the following communications system installed by default:

MODBUS RTU ® .

5�7�1�- CONNECTIONS

The RS-485 cable must be wired with twisted pair cable with mesh shield, with a maximum

distance between the

Dispenser and the master unit of

1200 metres

.

Up to 32

Dispensers can be connected to this bus.

Use an intelligent RS-232 to RS-485 network protocol converter to establish the

communications with the master unit.