6�- TECHNICAL FEATURES
AC Power supply
Rated voltage
230 / 120 V ~ Self-powered
Tolerance
80% ... 115 % Un
Frequency (Fn)
50 / 60 Hz
Consumption
< 2 W / 10 VA
Voltage measurement circuit
Rated voltage (Un)
230 V ~
Voltage measurement margin
± 20% Un
Frequency measurement margin
± 2% Fn
Current measurement circuit
Nominal current (In)
10 A Direct
Maximum current
40 A
Start-up current
< 20mA
Self-consumption of the current circuit
< 0.2 VA @ 10A
Measurement accuracy
Active energy measurement
Class 1 (IEC 62053-21)
Reactive energy measurement
Class 2 (IEC 62053-23)
Calculation and Processing
Microprocessor
ARM Cortex M3
Converter
16-bit
Memory
Data
RAM type, stored by Lithium battery
Setup, events, load curve
Non-volatile FLASH memory
Battery
Type
Lithium
Service life
> 15 years @ 35ºC under normal Dispenser operation
Clock
Source
Self-compensated quartz crystal oscillator
Drift
< 0.5 seconds/day at 25ºC
Auxiliary relay
Maximum voltage, open contacts
250V ~
Maximum current
3A ~
Maximum switching power
750 VA
Electrical working life (250 VAC / 5A)
1x10
5
operations
Mechanical working life
2 x10
7
operations
RS-485 Communications
Field bus
RS-485
Communications protocol
Modbus RTU
Baud rate
9600-19200-38400 bauds
Stop bits
1
Parity
none