CIRCUTOR DISPENSER Series User Manual
Page 47

Type 2 Contract:
Figure 50:Create a new tariff (Tariff conditions - Type 2 Contract)
Table 12:Create a new tariff (Tariff Conditions: Base Parameters)
Base Parameters
Parameter
Description
Range of values
Power base
(5)
Base power of the customer
100 ... 1000 W
Power multiplier
(5)
Multiplier of the base power
1 ...100
(5)
The Contracted power = Base power x Power multiplier
The price of energy and contracted power are fixed values that can vary according to the differ-
ent factors applied:
Excess and limiting factor of contracted power (See
)
Bonus and restriction factors applied to the price of energy. (See
Table 13:Create a new tariff (Tariff Conditions: Definition of factors)
Definition of factors
Parameter
Description
Range of values
Coefficients of contrated power
Excess
Factor that increases the maximum power of the in-
stallation when the micro-grid is in the bonus mode.
1 ...3
Limitation
Factor that decreases the maximum power of the
installation when the micro-grid is in the restriction
mode
0 ... 1
Coefficients of energy price
Bonus
Factor to reduce the price of energy when the mi-
cro-grid is in the bonus mode
0.4 ... 1
Restriction
Factor to increase the price of energy when the mi-
cro-grid is in the bonus mode
1.2 ... 3
47