9. Appendix
Cable Connection
Communication Protocol
Baud rate ........................................ 38400 bps
Data length ..................................... 8 bits
Parity .............................................. No parity
Stop bit .......................................... One bit
X on/off .......................................... None
Communications procedure ........... Full duplex
NOTE: Depending on the equipment, a lower baud rate may be recommended for long cable runs.
ᕦ PC Control Codes and Cable Connection
PC Control Codes
Function
Code Data
POWER ON
02H
00H
00H
00H
00H
02H
POWER OFF
02H
01H
00H
00H
00H
03H
INPUT SELECT COMPUTER 1
02H
03H
00H
00H
02H
01H
01H
09H
INPUT SELECT COMPUTER 2
02H
03H
00H
00H
02H
01H
02H
0AH
INPUT SELECT VIDEO
02H
03H
00H
00H
02H
01H
06H
0EH
INPUT SELECT S-VIDEO
02H
03H
00H
00H
02H
01H
0BH
13H
INPUT COMPONENT
02H
03H
00H
00H
02H
01H
1AH
22H
INPUT SELECT VIEWER
02H
03H
00H
00H
02H
01H
1FH
27H
PICTURE MUTE ON
02H
10H
00H
00H
00H
12H
PICTURE MUTE OFF
02H
11H
00H
00H
00H
13H
SOUND MUTE ON
02H
12H
00H
00H
00H
14H
SOUND MUTE OFF
02H
13H
00H
00H
00H
15H
ON SCREEN MUTE ON
02H
14H
00H
00H
00H
16H
ON SCREEN MUTE OFF
02H
15H
00H
00H
00H
17H
NOTE: Contact your local dealer for a full list of PC Control Codes if needed.
1
5
2
4
3
6
7
9
8
To GND of PC
NOTE: Pins 1, 4, 6 and 9 are no used.
NOTE: Jumper “Request to Send” and “Clear to Send”
together on both ends of the cable to simplify cable
connection.
To RxD of PC
To TxD of PC
To RTS of PC
To CTS of PC
PC Control Connector (D-SUB 9P)