Appendix, Example – Pilz ST SB DP S, SW paket PROFIBUS-DP User Manual
Page 37
PROFIBUS-DP-Slave Operating Manual
7-1
Appendix
Example
Data block DB 050 is selected for setting the parameters. The data block
is configured in OB 020. The configuration corresponds to Example 5 in
Chapter 4. SB 230 is called up in OB 001.
OB 020 Cold start ST
:A
DB 004
;Registered hardware on standard section
:L
KH B220
;Enter the code of the module (B220)
:T
DW 0027
;on slot 7
:
:A
DB 005
;Start address for Slave module
:L
KH 0000
;Start address (Offset) is 0
:T
DW 0007
;Slave module on slot 7
:
:L
KH 0000
;Reset the used flag
:T
MB 000.00
;in OB 001
:T
MW 030.00
;
:T
MW 010.00
;
:
:A
DB 050
;Data block for setting the parameters
;(input parameter “DB” from SB 230)
:L
KH 2500
;ID-Number
:T
DW 0258
;
:
:L
KH 0004
;Length of the diagnostic data [Bytes]
:T
DW 0259
;
:
:L
KH C1C0
;Configuration data
:T
DW 0384
;
:L
KH 00C0
;
:T
DW 0385
;
:L
KF 0010
;Reserved
:T
DW 0783
;
:L
KH 00F5
;Reserved
:T
DW 0795
;
:
:L
KF 0001
;Station address [0-126]
:T
DW 0800
;