Setting Parameters

4-8

PROFIBUS-DP-Slave Operating Manual

Special ID-Format
The ID-format occupies a maximum of three data words. Enter the
following values in the data block:

• When only output or input data is to be transferred:

.

.

DL

DR

.
DW 0384

Length-Byte

ID-Byte

.

.

.
DW 0813

KF

2

;Length of the configuration data in Bytes

.

.

.

• When input and output data is to be transferred simultaneously:

.

.

DL

DR

.
DW 0384

Length-Byte E ID-Byte

00

Length-Byte A

.

.

.
DW 0813

KF

3

;Length of the configuration data in Bytes

.

.

.

• When more than 64 Bytes of input and output data are to be transferred

simultaneously. Data must be transferred consecutively: first the 64
Bytes and then the remaining Bytes:

.

.

DL

DR

.
DW 0384

Length-Byte E ID-Byte

ID-Byte

Length-Byte A

Length-Byte A Length-Byte E

.

.

.
DW 0813

KF

6