9 Technical data

9.9.4

Voltage limit curves

1 S1 Switch-on time 100 % (100 K)

2 S2 - S10 On-off-switch < 100 %

3 Field weakening range

Characteristic line explanation:
M: Torque
M

F

: Torque for external ventilation

M

W

: Torque for water cooling

M

max

: Maximum torque

M

lim

: Voltage limit characteristic line

(torque limit without field weakening,
e. g. for n

N

= 3000 min

-1

)

M

limFW

: Voltage limit characteristic

line (torque limit with field weakening,
e. g. for n

N

= 3000 min

-1

)

The progression of these limit curves depends on a combination of the winding ver-
sions (K

EM

factors) and the intermediate circuit voltage ends of the respective servo

inverter.