9 type-specific data, 9 technical data – Pilz PMCtendo SZ.41/0/1/2/7/K/H/60/00 User Manual
Page 49
Operating Manual PMCtendo SZ
1002405-EN-03
49
9 Technical data
9.9
Type-specific data
IMPORTANT
Overheating!
Repainting the motor changes the thermal properties. The motor can not be operated
with the nominal data.
Retain the paint of the motor (matt black in accordance with RAL 9005).
The technical data apply to energy-optimized servo amplifier settings and were deter-
mined under the following thermal mounting conditions:
•
Mounting of motor with steel bracket on baseplate.
•
Minimum mounting surface area between motor and steel bracket, and between
steel bracket and baseplate according to the following table:
Ensure that comparable thermal mounting conditions exist in your system!
PMCtendo SZ motors – number of motor poles
Motor
Mounting area
between motor flange and
steel bracket
between steel bracket and
baseplate
S
B H [mm]
[m
2
]
SZ.3x
20
210 285
0,03
SZ.4x
20
210 285
0,03
SZ.5x
25
210 285
0,03
SZ.7x
25
285 285
0,03
SZ.8x
25
285 285
0,03
Motor
Number of poles – PZ [1]
SZ.3x
10
SZ.4x
14
SZ.5x
14
SZ.7x
14
SZ.8x
16
- PMCtendo SZ.51/0/1/2/7/K/H/30/00 PMCtendo SZ.41/0/1/2/7/K/H/30/00 PMCtendo SZ.55/1/1/2/7/F/H/30/00 PMCtendo SZ.75/0/1/2/7/K/H/30/00 PMCtendo SZ.71/0/1/2/7/K/H/30/00 PMCtendo SZ.75/0/1/2/7/W/H/30/00 PMCtendo SZ.42/1/1/2/7/K/H/30/00 PMCtendo SZ.52/1/1/2/7/K/H/30/00 PMCtendo SZ.72/0/1/2/7/K/H/60/00 PMCtendo SZ.55/0/2/2/7/K/H/45/00 PMCtendo SZ.44/0/1/2/7/K/H/30/00 PMCtendo SZ.73/0/1/2/7/K/H/45/00 PMCtendo SZ.52/0/1/2/7/K/H/30/00 PMCtendo SZ.73/0/1/2/7/F/H/30/00 PMCtendo SZ.51/0/2/2/7/K/H/30/00 PMCtendo SZ.53/0/1/2/7/K/H/30/00 PMCtendo SZ.53/0/1/2/7/K/H/60/00 PMCtendo SZ.51/1/1/2/7/K/H/60/00 PMCtendo SZ.75/0/2/2/7/F/H/30/00 PMCtendo SZ.73/0/1/2/7/K/H/30/00 PMCtendo SZ.41/1/2/2/7/K/H/60/00 PMCtendo SZ.41/0/2/2/7/K/H/60/00 PMCtendo SZ.75/2/1/2/7/F/H/45/00 PMCtendo SZ.55/0/2/2/7/F/H/30/00 PMCtendo SZ.51/1/2/2/7/K/H/60/00 PMCtendo SZ.51/0/2/2/7/K/H/60/00