beautypg.com

2 assignment: motor and power cable, 6 electrical installation – Pilz PMCtendo SZ.41/0/1/2/7/K/H/60/00 User Manual

Page 28

background image

Operating Manual PMCtendo SZ

1002405-EN-03

28

6 Electrical installation

6.2.2

Assignment: Motor and power cable

Assignment of connector size and minimum cross-section of power cores.

INFO
Note that the following assignment of the connector size to the minimum
cross-section ø

min

refers to a maximum cable length of 100 m.

PMCtendo SZ – convection-cooled (PMCtendo SZ.xx/.../K/...)

Motor

n

N

= 2000 min

-1

n

N

= 3000 min

-1

n

N

= 4500 min

-1

n

N

= 6000 min

-1

Connec-

tor size

ø

min

[mm

2

]

Connec-

tor size

ø

min

[mm

2

]

Connec-

tor size

ø

min

[mm

2

]

Connec-

tor size

ø

min

[mm

2

]

SZ.31

con.15

1,0

con.15

1,0

SZ.32

con.15

1,0

con.15

1,0

SZ.33

con.15

1,0

con.15

1,0

SZ.41

con.15

1,5

con.23

1,5

SZ.42

con.23

1,5

con.23

1,5

SZ.44

con.23

1,5

con.23

1,5

SZ.51

con.23

1,5

con.23

1,5

SZ.52

con.23

1,5

con.23

1,5

SZ.53

con.23

1,5

con.23

1,5

SZ.55

con.23

1,5

con.23

1,5

SZ.71

con.23

1,5

con.23

1,5

SZ.72

con.23

1,5

con.23

2,5

SZ.73

con.23

1,5

con.23

2,5

SZ.75

con.40

2,5

con.40

4,0

SZ.82

con.40

4,0

con.40

6,0

SZ.83

con.40

6,0

SZ.85

con.40

10,0