3 electrical data, 4 cooling, 1 convection cooling – Pilz PMCtendo SZ.41/0/1/2/7/K/H/60/00 User Manual
Page 40: 2 external fan, 9 technical data, 3 electrical data 9.4 cooling

Operating Manual PMCtendo SZ
1002405-EN-03
40
9 Technical data
9.3
Electrical Data
9.4
Cooling
9.4.1
Convection cooling
9.4.2
External fan
standard
Servo amplifier DC link connection
540 V
Winding
Three-phase, single-tooth design;
Star configuration, center is not led out
Current consumption
See section 9.9 Type-specific data
Current waveform
Sinusoidal
Protection class
I (protective grounding)
Insulation class
F as per EN 60034/VDE 0530
Standard
Optional
PMCtendo SZ
IC 410 Convection cooling
•
IC 416 Convection cooling by
external fan (IP 44)
•
Water cooling in A-side
flange
FL4
FL5
FL7
FL8
Motor SZ.4x
SZ.5x
SZ.7x
SZ.8x
U
N
230 V, -10% to +6%, 50/60 Hz
230 V, ±10 %,
50/60 Hz
I
N
[A]
0.07
0.1
0.1
0.2
P
N
[W]
10
14
14
26
Q
N
[m
3
/h]
59
160
160
420
G [dBA]
41
45
45
54
m [kg]
1.4
1.9
2.9
5.0
x
F
min
[mm]
20
20
30
30
Protection class
IP 44
Maximum ambient temperature
60°C
- PMCtendo SZ.51/0/1/2/7/K/H/30/00 PMCtendo SZ.41/0/1/2/7/K/H/30/00 PMCtendo SZ.55/1/1/2/7/F/H/30/00 PMCtendo SZ.75/0/1/2/7/K/H/30/00 PMCtendo SZ.71/0/1/2/7/K/H/30/00 PMCtendo SZ.75/0/1/2/7/W/H/30/00 PMCtendo SZ.42/1/1/2/7/K/H/30/00 PMCtendo SZ.52/1/1/2/7/K/H/30/00 PMCtendo SZ.72/0/1/2/7/K/H/60/00 PMCtendo SZ.55/0/2/2/7/K/H/45/00 PMCtendo SZ.44/0/1/2/7/K/H/30/00 PMCtendo SZ.73/0/1/2/7/K/H/45/00 PMCtendo SZ.52/0/1/2/7/K/H/30/00 PMCtendo SZ.73/0/1/2/7/F/H/30/00 PMCtendo SZ.51/0/2/2/7/K/H/30/00 PMCtendo SZ.53/0/1/2/7/K/H/30/00 PMCtendo SZ.53/0/1/2/7/K/H/60/00 PMCtendo SZ.51/1/1/2/7/K/H/60/00 PMCtendo SZ.75/0/2/2/7/F/H/30/00 PMCtendo SZ.73/0/1/2/7/K/H/30/00 PMCtendo SZ.41/1/2/2/7/K/H/60/00 PMCtendo SZ.41/0/2/2/7/K/H/60/00 PMCtendo SZ.75/2/1/2/7/F/H/45/00 PMCtendo SZ.55/0/2/2/7/F/H/30/00 PMCtendo SZ.51/1/2/2/7/K/H/60/00 PMCtendo SZ.51/0/2/2/7/K/H/60/00