beautypg.com

2 install motor, 5 installation – Pilz PMCtendo SZ.41/0/1/2/7/K/H/60/00 User Manual

Page 19

background image

Operating Manual PMCtendo SZ

1002405-EN-03

19

5 Installation

The following installation positions are admissible:

Particularly in installation position IM V3, ensure that no liquids from attachments can run
into the motor bearings.

5.2

Install motor

IMPORTANT

Material damage!

Impact and other forces can cause damage to the bearings, feedback system and motor
shaft.

 Do not hit the motor shaft or motor housing with a hammer or other tools.

 Do not apply any pressure, impact or high acceleration to the motor.
 Use backlash-free, frictionally engaged chucks or clutches.
 Always use the tightening thread provided in the motor shaft to fit or remove clutches,

gears or belt pulleys. Use suitable tools!

Motor

External fan

Minimum distance x

Fmin

[mm]

SZ.4x

FL4

20

SZ.5x

FL5

20

SZ.7x

FL7

30

SZ.8x

FL8

30

Admissible installation positions

IM B5

IM V1

IM V3