Mechanical data

312220

314220

315220

Dimensions

Height

76,0 mm

76,0 mm

76,0 mm

Width

12,6 mm

12,6 mm

12,6 mm

Depth

60,2 mm

60,2 mm

60,2 mm

Weight

44 g

46 g

46 g

Mechanical coding

Type

G

G

G

Colour

Yellow

Yellow

Yellow

The standards current on 2009­10 apply.

8.1

Safety characteristic data

Unit

Operating
mode

EN ISO
13849­1: 2008

PL

EN ISO
13849­1: 2008

Category

EN IEC 62061

SIL CL

EN IEC 62061

PFH

D

 [1/h]

EN ISO
13849­1: 2008

T

M

 [year]

Logic

Input

Digital inputs

1­channel

PL d

Cat. 2

SIL CL 2

9,10E­09

20

Digital inputs

2­channel

PL e

Cat. 3

SIL CL 3

3,10E­09

20

Digital inputs

1­ch., pulsed
light barrier

PL e

Cat. 4

SIL CL 3

2,91E­09

20

Output

SC outputs (2­
pole)

2­channel

PL e

Cat. 4

SIL CL 3

1,37E­09

20

If the module is operated at an ambient temperature above 60° C, the values stated in the
table for PFH

D

 and PFD will need to be doubled when a safety function is calculated.

All the units used within a safety function must be considered when calculating the safety
characteristic data.

INFORMATION

A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.