1 safety characteristic data, Safety characteristic data – Pilz PSSu E F 4DI User Manual
Page 33

Technical details
Operating Manual PSSu E F 4DI(T)(R)
21310EN05
33
Environmental data
312200
314200
315200
Supply interruptions
In accordance with the
standard
–
–
EN 50155
Class
–
–
S2, C1, C2
Max. operating height
above sea level
2000 m
5000 m
2000 m
Airgap creepage
In accordance with the
standard
EN 606641
EN 606641
EN 501241
Overvoltage category
II
II
OV2
Pollution degree
2
2
PD1
Protection type
In accordance with the
standard
EN 60529
EN 60529
EN 60529
Mounting area (e.g.
control cabinet)
IP54
IP54
IP51
Housing
IP20
IP20
IP20
Terminals
IP20
IP20
–
Mechanical data
312200
314200
315200
Material
Bottom
PC
PC
PC
Front
PC
PC
PC
Coding
PA
PA
PA
Mounting type
plugin
plugin
plugin
Dimensions
Height
76,0 mm
76,0 mm
76,0 mm
Width
12,6 mm
12,6 mm
12,6 mm
Depth
60,2 mm
60,2 mm
60,2 mm
Weight
44 g
45 g
45 g
Mechanical coding
Type
D
D
D
Colour
Yellow
Yellow
Yellow
The standards current on 200910 apply.
8.1
Safety characteristic data
Operating
mode
EN ISO
138491:
2008
PL
EN ISO
138491:
2008
Category
EN IEC
62061
SIL CL
EN IEC
62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
138491:
2008
T
M
[year]
1channel
PL d
Cat. 2
SIL CL 2
9,10E09
SIL 2
7,25E04
20
2channel
PL e
Cat. 3
SIL CL 3
3,10E09
SIL 3
1,85E05
20
1ch., pulsed
light barrier
PL e
Cat. 4
SIL CL 3
2,91E09
SIL 3
7,52E05
20
If the module is operated at an ambient temperature above 60° C, the values stated in the
table for PFH
D
and PFD will need to be doubled when a safety function is calculated.