Operating Manual PNOZ m ES Profibus
1002698­EN­03

11

4

Function description

4.1

Operation

The virtual inputs and outputs that are to be transferred via PROFIBUS are selected and
configured in the PNOZmulti Configurator. The base unit and the expansion modulePNOZ
m ES Profibus are connected via a jumper.

The station address is set via rotary switches. After the supply voltage is switched on or the
control system PNOZmulti 2 is reset, the expansion module PNOZ m ES Profibus is con­
figured and started automatically.

LEDs indicate the status of the expansion module on PROFIBUS.

The configuration is described in detail in the PNOZmulti Configurator's online help.

INFORMATION

The GSD file is available on the Internet at www.pilz.de.

4.2

Data access

The data is structured as follows:

}

Virtual data

Input range PNOZ m ES Profibus

The values for the inputs are set as an output in the Master and transferred to the
PNOZmulti 2.

Output range PNOZ m ES Profibus

The outputs are configured in the PNOZmulti Configurator and transferred to the
Master.

}

Status of LEDs:

Bits 0 … 4: Status of LEDs on the PNOZmulti 2

Bit 0: OFAULT

Bit 1: IFAULT

Bit 2: FAULT

Bit 3: DIAG

Bit 4: RUN

}

Data exchange is displayed in Bit 5.

}

Polling the usable data: 2 Bytes with the table number and segment number are sent by
the Master for access to the usable data table (15 Bytes are returned to the Master).

Detailed information on data exchange (tables, segments) is available in the document
"Communication Interfaces" in the section entitled "Fieldbus modules".