Display elements, 1 display elements for device diagnostics, 7operation – Pilz PNOZ mc2.1p EtherCAT 2 User Manual
Page 24: 2 display elements

7.2
Display elements
7
Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-2
7.2
Display elements
7200
Display elements
7-
Anzeige Legende aus-blink-blitz-1-2-flacker
Key:
7.2.1
Display elements for device diagnostics
Display elements for device diagnostics
7-
Betrieb_Anzeige_EtherCAT_BA
LED off
LED flashes once
LED flashes twice
LED flashes once
LED flashes
LED on
LED
LED status
Meaning
Link ACT 1
Green
Bus connection available at X1
Green
Data traffic present at X1
Bus connection is not available at X1
Link ACT 2
Green
Bus connection available at X2
Green
Data traffic present at X2
Bus connection not available at X2
RUN
Green
The device is in "OPERATIONAL" status
Green
The device is in "SAFE-OPERATIONAL" status
Green
The device is in "PRE-OPERATIONAL" status
The device is in "INIT" status
ERR
Red
Application Watchdog Timeout
Red
Sync Manager Watchdog Timeout.
Red
The Slave device application has changed the EtherCAT status independent-
ly: The "Change" parameter in the AL status register is set to 01 (change/er-
ror).
Red
Configuration error
EtherCAT communication is in operation