Pilz PZE X4VP 0,5/24VDC 4n/o fix User Manual
Page 10
![background image](https://www.manualsdir.com/files/762578/content/doc010.png)
PZE X4VP
Operating Manual PZE X4VP
1003202EN08
10
Relay outputs
777580
777581
777582
777583
Utilisation category
In accordance
with the standard EN 6094741
EN 6094741
EN 6094741
EN 6094741
Safetycontacts,
delayed, AC1 at
240 V
240 V
240 V
240 V
Min. current
0,01 A
0,01 A
0,01 A
0,01 A
Max. current
6,0 A
6,0 A
6,0 A
6,0 A
Max. power
1500 VA
1500 VA
1500 VA
1500 VA
Safetycontacts,
delayed, DC1 at
24 V
24 V
24 V
24 V
Min. current
0,01 A
0,01 A
0,01 A
0,01 A
Max. current
6,0 A
6,0 A
6,0 A
6,0 A
Max. power
150 W
150 W
150 W
150 W
Utilisation category
In accordance
with the standard EN 6094751
EN 6094751
EN 6094751
EN 6094751
Safety contacts,
delayed AC15 at
230 V
230 V
230 V
230 V
Max. current
3,0 A
3,0 A
3,0 A
3,0 A
Safety contacts
delayed DC13 (6
cycles/min) at
24 V
24 V
24 V
24 V
Max. current
4,0 A
4,0 A
4,0 A
4,0 A
Utilisation category
in accordance with
UL
Voltage
250 V AC G.U.
(same polarity)
250 V AC G.U.
(same polarity)
250 V AC G.U.
(same polarity)
250 V AC G.U.
(same polarity)
With current
6,0 A
6,0 A
6,0 A
6,0 A
Voltage
24 V DC G. U.
24 V DC G. U.
24 V DC G. U.
24 V DC G. U.
With current
6,0 A
6,0 A
6,0 A
6,0 A
Pilot Duty
B300, R300
B300, R300
B300, R300
B300, R300
Contact fuse protec
tion external, safety
contacts
In accordance
with the standard EN 6094751
EN 6094751
EN 6094751
EN 6094751