5 • Optical Mark Recognition (OMR)
5-4
SV40221 Rev. C
EOC - End of Collation
This is a mandatory mark within the Muti-Mark option, when used
on the Prime Sheet Set. This mark indicates that it is the last sheet
fed wthn the OMR set. This is the only mark used when using the
Single Mark option and can only be selected once within the code.
Options available:
• Present or Absent
STP - Stop
This mark is a processing feature which tells the machine to stop
once the completed Mail Piece has exited the machine.
Options available:
• Present or Absent
• All Sheets, Page 1 Only or Last Page Only
• Marked Piece to be left Unsealed (Yes or No)
SF(n) - Select Feed
These marks instruct the machine to select materal from specfed
feeders.
This feature is only available to select sheets when C, Z and Single
folds are used and the material is under 12“ (305mm) n length.
Selectively fed inserts are available for all types of folds and sheet
lengths within the specifications of the machine.
Up to 8 Select Feed Marks can be within the code. Up to 5 of these
marks can be allocated to specified feeders when creating a Job
Definition. The remaining marks will be ignored within that job.
Allowing 8 Select Feed Marks to be used gives greater flexibility in
reusing existing codes from production type machines which may
have a greater number of feeders.
Options available:
• Present or Absent
• All Sheets, Page 1 Only or Last Page Only